N110
Unfilled material, with a Vicat B/120 of
115°C according ISO 306. NORYL N110
has medium temperature resistance and good
impact properties over a wide temperature
range.
PX1112
Unfilled medium heat resistant material.
This grade offers improved impact resistance
to meet the ECE-dashboard standard. This
grade is especially designed for automotive
instrumental bodypanels.
PX9406N
Unfilled, halogen free (according VDE/DIN
472 part 813) flame retardant material with
medium heat resistance. This material is
V0 at 1.0 mm according to UL94. Noryl PX9406N
is especially designed for electrical applications.
SE0
Unfilled, flame retardant material with
a Vicat B/120 of 130°C according ISO
306. NORYL SE0 is V0 at 1.6 mm according
UL94 and halogen free according VDE/DIN
472 part 815.
SE90
Unfilled, flame retardant material with
a Vicat B/120 of 110°C according ISO
306. NORYL SE90 is V1 at 1.6 mm according
UL94 and halogen free according VDE/DIN
472 part 815. NORYL SE90 has a wide range
of applications, where flame retardancy
and medium temperature resistance is required.
GFN2
Standard 20% glass fiber reinforced material
with a HDT/A of 130°C according ISO
75. NORYL GFN2 can be used for all applications
where a higher modulus is required.
GFN3
Standard 30% glass filled material with
a HDT/A of 145°C according to ISO 75.
SE1GFN1
10% glass fibre reinforced, flame retardant
material with a HDT/A of 130°C according
ISO 75. NORYL SE1GFN1 is V1 at 1.47 mm according
UL94 and is halogen free according VDE/DIN
472 part 815. NORYL SE1GFN1 is designed
for electrical construction applications.
SE1GFN2
20% glass fibre reinforced, flame retardant
material with a HDT/A of 132°C according
ISO 75. NORYL SE1GFN2 is V1 at 1.47 mm according
UL94 and is halogen free according VDE/DIN
472 part 815. NORYL SE1GFN2 is designed
for electrical construction applications.
|